Configuration
Avira GmbH Avira AntiVir MailGate 58
Default for all parameters is:
0
A maximum (HighFillLevel) and minimum (LowFillLevel) threshold value
are defined for this purpose. As soon as the maximum value is reached, any other
emails are rejected with a temporary error message (SMTP Code 452: insufficient
system storage). Depending on the performance and load of the system, the
number of emails might slighty exceed the given threshold. By setting a valid
treshold value you specify at what level the incoming or outgoing queue is
“congested” or is “available”. New connections are not accepted until the number
of emails in the queue drops to the minimum value
(LowFillLevel) or below
this value.
On startup, each queue’s status is reset to “available”. If the number of emails in a
queue is greater or equal to the defined
HighFillLevel, the queue is considered
as “congested”. If the number of emails in a queue is less or equal to its
LowFillLevel, the queue is considered as “available”. If the number of emails in
a queue is less than the
HighFillLevel but larger than the LowFillLevel and
the queue’s previous state was “congested”, its state remain unchanged. To change
this status the number of emails has to drop to the
LowFillLevel again.
On a restart, Avira AntiVir MailGate will accept new emails regardless to the previous
state. The system does not recall a previous “congested” state of a queue.
When the set threshold value is reached, the postmaster is informed by SNMP
trap or email with the aid of the Notification Mechanisms function.
The number of emails counted will also contain those created by Avira AntiVir MailGate
itself.
The following statements are valid:
• The threshold value for both
HighFillLevel and LowFillLevel
is 0 (default).
• The threshold value for
HighFillLevel is greater than that for
LowFillLevel.
If invalid statements are made, Avira AntiVir MailGate will not start.
PollPeriod
Scan queue (not in milter mode)
This option defines the interval at which the program scans the email queue for
viruses and malware (in seconds).
Syntax:
PollPeriod "non-negative number"
Example:
PollPeriod 30
Default:
Kommentare zu diesen Handbüchern